Artery Research

Volume 14, Issue C, June 2016, Pages 6 - 9

Repeatability measurements of second systolic shoulder of the radial waveform and peripheral augmentation index with the OMRON HEM-9000AI device in a sample of young Mexican subjects

Authors
Carlos G. Ramos*, Guillermo A. Alanis, Fernando Grover, David Cardona, Mayra Jimenez, Victor Guzman, Patricia Quezada, Sara Pascoe, Leonel Garcia, Sylvia E. Totsuka, Ernesto G. Cardona
Department of Physiology, Faculty of Medicine, University Center for Health Sciences, Arterial Stiffness Laboratory, University of Guadalajara, Mexico, Guadalajara, Mexico
*Corresponding author. Tel.: +52 3331562545. E-mail address: md_crb@hotmail.com (C.G. Ramos).
Corresponding Author
Carlos G. Ramos
Received 8 December 2015, Revised 16 January 2016, Accepted 4 February 2016, Available Online 19 February 2016.
DOI
10.1016/j.artres.2016.02.002How to use a DOI?
Keywords
Central aortic pressure; Central systolic blood pressure; Second systolic shoulder of the radial waveform; Peripheral augmentation index
Abstract

The development of non-invasive technology to perform pulse wave analysis and accurately determine central blood pressure has facilitated the study of central blood pressure as a physiologic and biomarker parameter. Central systolic blood pressure (cSBP) has been shown to be significantly associated with adverse outcome such as mortality and associated with adverse outcome. One of the most commonly evaluated features of the arterial pressure waveforms is augmentation index (AIx). Nowadays, there are multiple devices that have been developed for calculate AIx at peripheral arteries. The aim of our study was to assess the repeatability measurements of second systolic shoulder of the radial waveform (pSBP2) and peripheral augmentation index (pAIx) using the OMRON HEM-9000AI. 36 young subjects were studied. The paired t student test showed no significant difference. The mean difference between the two consecutive measures of pSBP2 was 0.3 ± 4; P = 0.58, pAIx (0.3 ± 7; P = 0.80) and pAIx75 (0.5 ± 6.6; P = 0.62). This study demonstrates good repeatability and reliability of this method in our study population, compared to other populations the variability between measurements.

Copyright
© 2016 Association for Research into Arterial Structure and Physiology. Published by Elsevier B.V. All rights reserved.
Open Access
This is an open access article distributed under the CC BY-NC license.

Download article (PDF)
View full text (HTML)

Journal
Artery Research
Volume-Issue
14 - C
Pages
6 - 9
Publication Date
2016/02/19
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2016.02.002How to use a DOI?
Copyright
© 2016 Association for Research into Arterial Structure and Physiology. Published by Elsevier B.V. All rights reserved.
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - Carlos G. Ramos
AU  - Guillermo A. Alanis
AU  - Fernando Grover
AU  - David Cardona
AU  - Mayra Jimenez
AU  - Victor Guzman
AU  - Patricia Quezada
AU  - Sara Pascoe
AU  - Leonel Garcia
AU  - Sylvia E. Totsuka
AU  - Ernesto G. Cardona
PY  - 2016
DA  - 2016/02/19
TI  - Repeatability measurements of second systolic shoulder of the radial waveform and peripheral augmentation index with the OMRON HEM-9000AI device in a sample of young Mexican subjects
JO  - Artery Research
SP  - 6
EP  - 9
VL  - 14
IS  - C
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2016.02.002
DO  - 10.1016/j.artres.2016.02.002
ID  - Ramos2016
ER  -