Proceedings of the 1st Unimed International Conference on Sport Science (UnICoSS 2019)

Agility Side Step Test Development Test Device Motion Sensor Based

Authors
Wahyu Cahyo Baskoro, Imran Akhmad, Nurhayati Simatupang
Corresponding Author
Wahyu Cahyo Baskoro
Available Online 9 March 2020.
DOI
10.2991/ahsr.k.200305.001How to use a DOI?
Keywords
agility, development, motion sensor
Abstract

Agility is a very important component in sports activities. Almost every sport requires agility as a differentiator for everyone’s physical skills. Various agility instruments have been created such as Side Step Test, Illinois Agility Run, Shuttle Run Test, Zig Zag Test, T-Test, Agility Cone Drill, Arrowhead Drill, 20 Yard Agility, Balsom Agility Test, and others (www.topendsport.com). Some of the agility test instruments above are instruments that have been tested and developed in various countries. The weakness in conventional side step test implementation with observations using the eyes is when the teste does no movement whether the feet have crossed the left side or the right side. The method used in this research is Research and Development Sources of data in this study were obtained from athletes in the form of treatment tests and measurement of agility side step tests based on motion sensors. Side step test is a form of agility test that aims to measure agility (where the sideways movement is changed in the opposite direction of motion). With the existence of the side step test based on the motion sensor based, it is expected to help facilitate the implementation of the test to be more effective and the results are more valid. In addition this side step test tool is also in accordance with advances in digital technology so that it is more relevant.

Copyright
© 2020, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 1st Unimed International Conference on Sport Science (UnICoSS 2019)
Series
Advances in Health Sciences Research
Publication Date
9 March 2020
ISBN
978-94-6252-919-9
ISSN
2468-5739
DOI
10.2991/ahsr.k.200305.001How to use a DOI?
Copyright
© 2020, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Wahyu Cahyo Baskoro
AU  - Imran Akhmad
AU  - Nurhayati Simatupang
PY  - 2020
DA  - 2020/03/09
TI  - Agility Side Step Test Development Test Device Motion Sensor Based
BT  - Proceedings of the 1st Unimed International Conference on Sport Science (UnICoSS 2019)
PB  - Atlantis Press
SP  - 1
EP  - 2
SN  - 2468-5739
UR  - https://doi.org/10.2991/ahsr.k.200305.001
DO  - 10.2991/ahsr.k.200305.001
ID  - Baskoro2020
ER  -