Application of Principal Component Analysis in Measuring Water Supply Capacity
- DOI
- 10.2991/msmee-17.2017.133How to use a DOI?
- Keywords
- Water Supply System Evaluation , PCA, GEM.
- Abstract
Measuring the water supply capacity is very complex with many impact factors. It is difficult to find the main factors. After constant comparing and calculating, I finally determine 12 factors have greater impact on sustainable development. Due to the influence factors is very complex and linked between them, I adopt the way of principal component analysis (PCA) to reduce the factors as much as possible. I define four indicators, which are Probability of Water Supply (IP), Reliability of Water Supply (IR), Water Utilization Rate (IW) and Efficiency of Water Utilization (IE). The grades (> ,= ,<) of them respectively represent the indicators are high, middle and low.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Dejie Zhao PY - 2017/05 DA - 2017/05 TI - Application of Principal Component Analysis in Measuring Water Supply Capacity BT - Proceedings of the 2017 2nd International Conference on Materials Science, Machinery and Energy Engineering (MSMEE 2017) PB - Atlantis Press SP - 689 EP - 692 SN - 2352-5401 UR - https://doi.org/10.2991/msmee-17.2017.133 DO - 10.2991/msmee-17.2017.133 ID - Zhao2017/05 ER -