Numerical and Experimental Study of Temperature Distribution in an Air-cooled Refrigerator Freezer
- DOI
- 10.2991/mseee-18.2018.36How to use a DOI?
- Keywords
- Air-cooled refrigerator, temperature distribution, numerical simulation, freezer
- Abstract
A numerical model of flow and temperature field in an air-cooled refrigerator freezer was established by CFD method and was validated by experiments. The results show that the simulation temperature is slightly lower than the experimental results; the maximum relative error is 1.89%. The numerical results show that the shelves divided the freezer into three temperature zones, the vortexes were formed in the door boxes and vegatable box, which weaken the convective heat transfer. Rising the air velocity will improve the uniformity of the temperature distribution in the refrigerator. The research provided a reference for optimal design of the freezer in the air-cooled refrigerator.
- Copyright
- © 2018, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Jingwei Zeng AU - Qifeng Zhu AU - Dongdong Xue AU - Hongwei Zhang PY - 2018/08 DA - 2018/08 TI - Numerical and Experimental Study of Temperature Distribution in an Air-cooled Refrigerator Freezer BT - Proceedings of the 2nd International Conference on Material Science, Energy and Environmental Engineering (MSEEE 2018) PB - Atlantis Press SP - 207 EP - 211 SN - 2352-5401 UR - https://doi.org/10.2991/mseee-18.2018.36 DO - 10.2991/mseee-18.2018.36 ID - Zeng2018/08 ER -