Research on Evaluation Method of Transient Overvoltage Hazard Based on S-Transform
- DOI
- 10.2991/isaeece-17.2017.71How to use a DOI?
- Keywords
- Transient over-voltage, Fourier transform, S-transform, transformation insulation
- Abstract
In field operation, the transformer with good insulation design and insulation condition may failure caused by transient over-voltage. The accumulation of transient overvoltage reduces the reliability of transformer internal insulation without signs. Therefore, it is necessary to assess the over-voltage hazards on the transformer. In order to evaluate the transient damage of transformers in operation, the transient overvoltage evaluation method based on S transform is proposed in this paper. Firstly, a method based on traditional Fourier transform is introduced. Secondly, the defects of traditional Fourier transform are analyzed. Finally, a transient overvoltage evaluation based on S transform is proposed to overcome the shortcomings of traditional Fourier transform method.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Haifeng Ye AU - Xiang Tian AU - Hao Wu AU - Yabo Li AU - Zhen Wu AU - Guoming Ma PY - 2017/03 DA - 2017/03 TI - Research on Evaluation Method of Transient Overvoltage Hazard Based on S-Transform BT - Proceedings of the 2017 2nd International Symposium on Advances in Electrical, Electronics and Computer Engineering (ISAEECE 2017) PB - Atlantis Press SP - 368 EP - 374 SN - 2352-5401 UR - https://doi.org/10.2991/isaeece-17.2017.71 DO - 10.2991/isaeece-17.2017.71 ID - Ye2017/03 ER -