Proceedings of the International Joint Conference on Science and Engineering (IJCSE 2020)

Centrifugal Pump Bearing Analysis With Amplitude Indicator Using Vibration Meter

Authors
Juan Ardi Kusuma, Firman Yasa Utama
Corresponding Author
Juan Ardi Kusuma
Available Online 24 November 2020.
DOI
10.2991/aer.k.201124.073How to use a DOI?
Keywords
Bearing, Reliability, Amplitude, Preventive Maintenance
Abstract

Centrifugal pumps In this company serve to distribute plant waste to wastewater treatment installations in order to reduce waste levels. One component of centrifugal pump on wastewater treatment plant to be aware of is bearing. The treatment has been used corrective maintenance which is when the machine is off or the appliance has a new damage done repair. Unavailability of preventive maintenance scheduling caused undetection of damage factor that occurred on the bearing while operating. The purpose of this research is to know how to identify bearing damage in order to improve the performance of centrifugal pumps and to determine the scheduling of maintenance - preventive. This testing method uses applied research. The result of this research is the identification of damage to the pump obtained the lowest reliability value of 74.2% and the Amplitudo value of 1.91 m/s2. Where the minimum reliability limit is 80% and the maximum amplitude limit is 1.8 m/s2. Bearing conditions indicate damage. The action is derived from the sound of the bearing and vibration testing using vibration meter. So the scheduling of maintenance preventive can be done from daily, weekly, monthly and yearly according to the results of the research.

Copyright
© 2020, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the International Joint Conference on Science and Engineering (IJCSE 2020)
Series
Advances in Engineering Research
Publication Date
24 November 2020
ISBN
978-94-6239-276-2
ISSN
2352-5401
DOI
10.2991/aer.k.201124.073How to use a DOI?
Copyright
© 2020, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Juan Ardi Kusuma
AU  - Firman Yasa Utama
PY  - 2020
DA  - 2020/11/24
TI  - Centrifugal Pump Bearing Analysis With Amplitude Indicator Using Vibration Meter
BT  - Proceedings of the International Joint Conference on Science and Engineering (IJCSE 2020)
PB  - Atlantis Press
SP  - 408
EP  - 414
SN  - 2352-5401
UR  - https://doi.org/10.2991/aer.k.201124.073
DO  - 10.2991/aer.k.201124.073
ID  - Kusuma2020
ER  -