Analysis of system transient response and its effect on sound speed measurement based on TFCW
- DOI
- 10.2991/icmse-15.2015.311How to use a DOI?
- Keywords
- Sound speed, Measurement system, Transient response.
- Abstract
This paper carries out a research to analyze system transient response and its effect on sound speed measurement based on two frequency continuous wave (TFCW). Because the bandwidth of an actual measurement system is limited, the received signal is generally polluted by a system transient response, and it can significantly degrade the measurement accuracy of sound speed. We consider the actual system as a bandpass system. The phenomenon of transient response can be clearly noted, and simulations show that its effect on sound speed measurement is related to the starting time, the observation length of signal and the system bandwidth. To validate our research, we finally designed an experimental system to perform a sound speed measurement, and the experimental results are consistent with the simulations.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Chao Zhou AU - Chunjie Qiao AU - Zhigang Huang AU - Weihua Dai PY - 2015/12 DA - 2015/12 TI - Analysis of system transient response and its effect on sound speed measurement based on TFCW BT - Proceedings of the 2015 6th International Conference on Manufacturing Science and Engineering PB - Atlantis Press SP - 1710 EP - 1716 SN - 2352-5401 UR - https://doi.org/10.2991/icmse-15.2015.311 DO - 10.2991/icmse-15.2015.311 ID - Zhou2015/12 ER -