Performance Analysis of Air Conditioning System Using Freon R22 and Musicool (Mc 22) Based on Speed of Variation of Air Conditioning Condensers

Authors
Jhon A. Wabang*, Edwin P. D. Hattuedwinhattu10@gmail.com, Jufra D. J. Abanatabanatjuf@gmail.com
Mechanical Engineering, State Polytechnic of Kupang, Kupang, Indonesia
Corresponding Author
Jhon A. Wabang
Available Online 30 November 2021.
DOI
10.2991/aer.k.211129.060How to use a DOI?
Keywords
air conditioning system; freon; hydrocarbon (MC 22)
Abstract

Air conditioning system is a cooling system whose function is to condition the air according to the desired needs. Air conditioning can be done in workspaces, foodstuffs, or industrial products that are desirable in accordance with the needs. The cooling system used is a steam compression system. The problems faced so far are the amount / weight of the refrigerant (cooling material) and the rotational speed of the condenser fan to the cooling capacity of the cooling system. The refrigerant that used in this research is R22 refrigerant and hydrocarbon refrigerant (Musucool / MC 22). The purpose of using these two refrigerants is to find out the performance of the air conditioning system by using R22 refrigerant and hydrocarbon refrigerant (MC 22) through variations in fan rotation speed on the condenser. The method used in this research is an experimental method with an existing refrigeration machine, which is a refrigerant machine 22 (R22). The testing is carried out in stages, namely vacuuming the system, charging refrigerant in the form of Freon R22 and also hydrocarbon refrigerant (MC 22) which is carried out on the basis of the weight / mass of the two types of refrigerant, then the air velocity varies in the condenser. Furthermore, the system working pressure measurements are measured either low pressure (LP) and high pressure (HP) of the system as well as performance measurement in the form of the Coefficient Of Performance (COP) system and current consumption that occurs. The test results show that at low rotation (200 rpm), the system pressure is higher, namely 100 psi for R22 and 95 for R290, while at high rotation (750 rpm), the system pressure is 91 psi for R22 and 90 for R290. Likewise, the consumption of electric current from 2.9 A to 2.2 A on R22 and 2.2 to 2.0 on R290.

Copyright
© 2021 The Authors. Published by Atlantis Press International B.V.
Open Access
This is an open access article under the CC BY-NC license.

Download article (PDF)

Volume Title
Proceedings of the International Conference on Innovation in Science and Technology (ICIST 2020)
Series
Advances in Engineering Research
Publication Date
30 November 2021
ISBN
978-94-6239-472-8
ISSN
2352-5401
DOI
10.2991/aer.k.211129.060How to use a DOI?
Copyright
© 2021 The Authors. Published by Atlantis Press International B.V.
Open Access
This is an open access article under the CC BY-NC license.

Cite this article

TY  - CONF
AU  - Jhon A. Wabang
AU  - Edwin P. D. Hattu
AU  - Jufra D. J. Abanat
PY  - 2021
DA  - 2021/11/30
TI  - Performance Analysis of Air Conditioning System Using Freon R22 and Musicool (Mc 22) Based on Speed of Variation of Air Conditioning Condensers
BT  - Proceedings of the International Conference on Innovation in Science and Technology (ICIST 2020)
PB  - Atlantis Press
SP  - 283
EP  - 286
SN  - 2352-5401
UR  - https://doi.org/10.2991/aer.k.211129.060
DO  - 10.2991/aer.k.211129.060
ID  - Wabang2021
ER  -