Measurement of Water Level of Drum of Thermal Generator Set
Authors
Xian Zhang
Corresponding Author
Xian Zhang
Available Online July 2015.
- DOI
- 10.2991/icismme-15.2015.252How to use a DOI?
- Keywords
- Water Level of Drum; Water level measurement.
- Abstract
During operation of the thermal power plant, the water level of drum is the important monitoring parameter, involving not only the DAS system monitoring, but also input of auto and interlock protection of water supply. From the actual situation, this paper analyzes the cause and harm of inaccurate measurement of water level, and puts forward the proper installment method through analysis of measurement principle. At the same time, for problems easy to occur in installation and commissioning, this paper carries out summarization and puts forward the improvement opinion.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Xian Zhang PY - 2015/07 DA - 2015/07 TI - Measurement of Water Level of Drum of Thermal Generator Set BT - Proceedings of the First International Conference on Information Sciences, Machinery, Materials and Energy PB - Atlantis Press SP - 1184 EP - 1187 SN - 1951-6851 UR - https://doi.org/10.2991/icismme-15.2015.252 DO - 10.2991/icismme-15.2015.252 ID - Zhang2015/07 ER -