Discussion on Misclassification of Ultrasonic Cross-hole Detection Method in Bored Piles
- DOI
- 10.2991/iceep-18.2018.289How to use a DOI?
- Keywords
- Cross-hole detection method; Bored pile; Misjudgment
- Abstract
Ultrasonic cross-hole detection method is widely used for the quality detection of bored piles due to its comprehensive, detailed and accurate results, and no restrictions on the lengths and ratios of length to diameter of piles. However, because of the quality problems of the instrument or operation rather than the quality of the pile itself, the ultrasonic testing results are not good enough, and the misjudgment often occurs. The paper analyzed the characteristics and the causes of the problems, and discussed how to identify and reduce the occurrence of misjudgment by summarizing the experiences from the ultrasonic testing results of the 5,000 piles for the 53km North-South Expressway project in Algeria, and combining relevant specifications and literatures.
- Copyright
- © 2018, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Likui Huang AU - Enkuan Tang AU - Ganming Yi AU - Wenbin Wu AU - Qing Shen PY - 2018/09 DA - 2018/09 TI - Discussion on Misclassification of Ultrasonic Cross-hole Detection Method in Bored Piles BT - Proceedings of the 2018 7th International Conference on Energy and Environmental Protection (ICEEP 2018) PB - Atlantis Press SP - 1604 EP - 1607 SN - 2352-5401 UR - https://doi.org/10.2991/iceep-18.2018.289 DO - 10.2991/iceep-18.2018.289 ID - Huang2018/09 ER -