Performance Study Of 2 Pk Split AC Through Variation Of Capillary Tube For 0.070 Inch And 0.080 Inch Diameter With R22 And R290 Refrigerants
- DOI
- 10.2991/978-94-6463-364-1_53How to use a DOI?
- Keywords
- Air Conditioning System; Capillary Tube; Hydrocarbon (MC 22)
- Abstract
The capillary tube is one of the most important components in the air cooling system (AC), whose function is to reduce the pressure and temperature of the refrigerant in the AC system. The dimensions of the capillary tube influence the performance of an air cooling system, therefore this research was carried out by varying the dimensions of the capillary tube in the form of varying the diameter of the capillary pipe in a 2 PK split AC to determine the performance of the AC. The refrigerant material used is refrigerant (R22 and R290/hydrocarbon (MC22). The results showed that the performance of the The the capillary tube for a diameter of 0.070 inches with refrigerant R22, Coefficient of Performance (COP) was 7.41 Refrigeration Efficiency 57.11%, cooling capacity 5.08 kW, and refrigeration effect 175.01 kJ/kg and then for capillary tube for a diameter of 0.080 inches with refrigerant R290, Coefficient of Performance (COP) was 6.76, Refrigeration Efficiency 52.15%, cooling capacity 8.89 kW, and refrigeration effect 306.57 kJ/kg.
- Copyright
- © 2024 The Author(s)
- Open Access
- Open Access This chapter is licensed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/), which permits any noncommercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made.
Cite this article
TY - CONF AU - Jhon Arnoldos Wabang AU - Edwin P. D. Hattu AU - Nasaruddin AU - Aris Samule AU - Marselinus Doreng AU - Fransisko P. Niron AU - Amirudin Abdullah AU - Duran Hore AU - Jufra D. J. Abanat AU - Antonius Pangalinan PY - 2024 DA - 2024/02/17 TI - Performance Study Of 2 Pk Split AC Through Variation Of Capillary Tube For 0.070 Inch And 0.080 Inch Diameter With R22 And R290 Refrigerants BT - Proceedings of the International Conference on Applied Science and Technology on Engineering Science 2023 (iCAST-ES 2023) PB - Atlantis Press SP - 571 EP - 578 SN - 2352-5401 UR - https://doi.org/10.2991/978-94-6463-364-1_53 DO - 10.2991/978-94-6463-364-1_53 ID - Wabang2024 ER -