A synchronous motor rotor initial position detection methods
- DOI
- 10.2991/icadme-17.2017.48How to use a DOI?
- Keywords
- IPMSM; initial position; rotor poles; tracking differentiator
- Abstract
Sources of error are took into account while applying high frequency rotation voltage injection method to interior permanent magnet synchronous motor (IPMSM). A new method using the phase difference of two new tracking differentiator (NTD) output signals for solving the initial position of the rotor poles on the basis of the derivation of high frequency positive, negative sequence current is proposed. Method only need four parameters bus voltage, electrical angle of high-frequency signal and the inductance of direct and quadric axis, without using PI regulator or Luneburg observer. The experimental results verify the accuracy of the detection. The method can be used to solve the starting problem of the IPMS
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Zhengshi Chen AU - Xiaowen Liao AU - Mei Liu PY - 2017/07 DA - 2017/07 TI - A synchronous motor rotor initial position detection methods BT - Proceedings of the 2017 7th International Conference on Advanced Design and Manufacturing Engineering (ICADME 2017) PB - Atlantis Press SP - 244 EP - 248 SN - 2352-5401 UR - https://doi.org/10.2991/icadme-17.2017.48 DO - 10.2991/icadme-17.2017.48 ID - Chen2017/07 ER -