Study on blasting vibration reduction technology by digital detonator
- DOI
- 10.2991/icadme-15.2015.245How to use a DOI?
- Keywords
- Hole-bottom air space charging; Air ration; Frequency band; Blasting vibration; Stress
- Abstract
The delay precision of common detonator is not good, the actual time delay often have big difference with blasting design in real blasting engineering, and the blasting effect is difficult to control. While high precision digital detonators are instead of chemical drugs by original electronic control chip, so it has very high precision delay, and it is widely used in reducing blasting vibration and improving blasting effect. According to the contrast analysis of blasting vibration generated by digital electronic detonator and common detonator in actual situation, the total energy ratio of energy and D7 band ratio is regarded as index. Comparing results of the vibration reduction effect of digital detonator with common detonator proves that digital detonator in reducing blasting vibration effect is on superiority. It is worth to be promoted.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - E.A. Chi AU - M.S. Zhao AU - Q. Kang PY - 2015/10 DA - 2015/10 TI - Study on blasting vibration reduction technology by digital detonator BT - Proceedings of the 5th International Conference on Advanced Design and Manufacturing Engineering PB - Atlantis Press SP - 1326 EP - 1331 SN - 2352-5401 UR - https://doi.org/10.2991/icadme-15.2015.245 DO - 10.2991/icadme-15.2015.245 ID - Chi2015/10 ER -