Proceedings of the 2015 International conference on Applied Science and Engineering Innovation

Air Quality Index Monitoring System Based on Flow Point of BD

Authors
Yuxiang Liu, Zhengjun Hao, Bing Fan, Rong Tang, Yanan Cao
Corresponding Author
Yuxiang Liu
Available Online May 2015.
DOI
10.2991/asei-15.2015.252How to use a DOI?
Keywords
Automatic flow air PM2.5 monitoring, The BD Positioning system, 3G data transmission, tracking robot.
Abstract

China is annual faced with a large area of bad weather such as fog and haze, which make a serious impact on people's daily lives, traffic congestion and other flight delays. Currently, the monitoring towards air quality are mostly procured through static monitoring station or artificial flow monitoring, whose limitations lie in the incomplete data, heavy workload of the artificial flow monitoring and the poor quality. Even the bad weather may result in serious damage to people. Therefore paper designs a mobile air quality monitoring system. The system uses a robot which has its own air quality monitoring instrument to flow monitoring autonomously; takes the advantage of the BD information systems,3G communication module to locate different sites; adopts the 3G data transmission modules, -ray method to monitor the air quality of PM2.5.Besides,the system uses camera to collect relevant environmental information, take the speed and direction of robot into control by video identification guide wire and intelligent PID control algorithm. The air quality monitoring system designed in the paper makes a perfect combination of hardware and software.

Copyright
© 2015, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2015 International conference on Applied Science and Engineering Innovation
Series
Advances in Engineering Research
Publication Date
May 2015
ISBN
978-94-62520-94-3
ISSN
2352-5401
DOI
10.2991/asei-15.2015.252How to use a DOI?
Copyright
© 2015, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Yuxiang Liu
AU  - Zhengjun Hao
AU  - Bing Fan
AU  - Rong Tang
AU  - Yanan Cao
PY  - 2015/05
DA  - 2015/05
TI  - Air Quality Index Monitoring System Based on Flow Point of BD
BT  - Proceedings of the 2015 International conference on Applied Science and Engineering Innovation
PB  - Atlantis Press
SP  - 1283
EP  - 1289
SN  - 2352-5401
UR  - https://doi.org/10.2991/asei-15.2015.252
DO  - 10.2991/asei-15.2015.252
ID  - Liu2015/05
ER  -