Simulation and Analysis of 75mm Gas-liquid Cyclone Flow Field
Authors
Liang Ma, Pen Qian, Jingping Wu, Zhaoyuan Bai, Qiang Yang
Corresponding Author
Liang Ma
Available Online December 2013.
- DOI
- 10.2991/wiet-13.2013.24How to use a DOI?
- Keywords
- CFD; Gas-liquid cyclone; Simulation; Axial velocity
- Abstract
The inside flow field of a gas–liquid cyclone separator with a diameter of 75 mm was simulated with the computational fluid dynamics (CFD). Results showed that a variation of inlet flow rate significantly changes the inside flow field structure and affects separation efficiency. The axial velocity of sections at four different positions was studied. All absolute values of the axial velocity increased with increased inlet flow rate. The regional line diagram of axial velocity shows that the increased inlet flow rate significantly increases the axial velocity area in the upward direction and decreases the same in the downward direction.
- Copyright
- © 2013, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Liang Ma AU - Pen Qian AU - Jingping Wu AU - Zhaoyuan Bai AU - Qiang Yang PY - 2013/12 DA - 2013/12 TI - Simulation and Analysis of 75mm Gas-liquid Cyclone Flow Field BT - Proceedings of the AASRI Winter International Conference on Engineering and Technology (AASRI-WIET 2013) PB - Atlantis Press SP - 106 EP - 109 SN - 1951-6851 UR - https://doi.org/10.2991/wiet-13.2013.24 DO - 10.2991/wiet-13.2013.24 ID - Ma2013/12 ER -