Artery Research

Volume 7, Issue 3-4, September 2013, Pages 119 - 119

P2.03 AORTIC, BUT NOT RADIAL PRESSURE GIVES A MODEL INDEPENDENT ESTIMATE OF CEREBRAL ARTERY CRITICAL CLOSING PRESSURE

Authors
M.O. Kim1, M. Butlin1, Y. Li2, F. Wei2, J. Wang2, M. O’Rourke1, 2, A.P. Avolio1
1Australian School of Advanced, Macquarie University Sydney Australia
2Ruijin Hospital, Shanghai, St. Vincent’s Clinic, Sydney
Available Online 11 November 2013.
DOI
10.1016/j.artres.2013.10.065How to use a DOI?
Abstract

Objectives: Cerebral artery critical closing pressure (CCP) is an estimated parameter with no single accepted method of calculation. Variation between methods could be significant. This study investigates two models to estimate CCP using arterial blood pressure (BP) and middle cerebral artery flow velocity (FV) waveforms, quantifying the difference between radial and aortic BP as the BP input signal.

Methods: Suspected and untreated hypertensive subjects (n=445, 203 female, 50±10 years, range 21 to 73 years old), referred to Ruijin Hospital in Shanghai, China, for 24-hours BP monitoring, were recruited. Radial BP and FV waveforms were acquired by applanation tonometry and transcranial Doppler respectively. Aortic BP waveforms were synthesised from the radial waveform using a validated transfer function (SphygmoCor®). CCP was estimated using the relationship between BP and FV waveforms by both linear regression (LR), and the first harmonic (H1) in Fourier decomposition. The difference between the two models was quantified if the BP waveform input signal was radial or aortic and compared by Student’s paired t-test.

Results: Use of aortic instead of radial BP resulted in a 29% increase in estimated CCP using the LR model, and 25% increase using the H1 model (Figure, p<0.001). Radial BP resulted in variation between the models (4%, p<0.001). Aortic BP did not cause this variation (0.6%, p=0.49).

Conclusions: Aortic, but not radial pressure gave a model independent estimate of CCP. However, estimated CCP within a model was significantly different depending on whether radial or aortic pressure was used.

Open Access
This is an open access article distributed under the CC BY-NC license.

Download article (PDF)
View full text (HTML)

Journal
Artery Research
Volume-Issue
7 - 3-4
Pages
119 - 119
Publication Date
2013/11/11
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2013.10.065How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - M.O. Kim
AU  - M. Butlin
AU  - Y. Li
AU  - F. Wei
AU  - J. Wang
AU  - M. O’Rourke
AU  - A.P. Avolio
PY  - 2013
DA  - 2013/11/11
TI  - P2.03 AORTIC, BUT NOT RADIAL PRESSURE GIVES A MODEL INDEPENDENT ESTIMATE OF CEREBRAL ARTERY CRITICAL CLOSING PRESSURE
JO  - Artery Research
SP  - 119
EP  - 119
VL  - 7
IS  - 3-4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2013.10.065
DO  - 10.1016/j.artres.2013.10.065
ID  - Kim2013
ER  -