Artery Research

Volume 8, Issue 4, December 2014, Pages 151 - 151

P8.1 FEASIBILITY OF 24-HOUR CENTRAL BLOOD PRESSURE MEASUREMENTS–THE ISAR HEMODIALYSIS STUDY

Authors
M. Baumanna, M. Bauhofera, S. Wassertheurerb, S. Tholena, C. Hausera, Y. Suttmanna, A.-L. Hasenaua, U. Heemanna, C. Schmaderera
aUniversität München, Munich, Germany
bAIT Austrian Institute of Technology, Vienna, Austria
Available Online 4 November 2014.
DOI
10.1016/j.artres.2014.09.176How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Background: Calculation of central blood pressure (BP) values using oscillometric systems at brachial level obtain feasible office values, but also allow a 24-hour determination of 24-hour central BP. We were interested in the feasibility of the determination of 24-hour central BP measurements in end-stage renal disease patients.

Methods: In the ISAR hemodialysis study 556 chronic hemodialysis patients were investigated. 24-hour central BP was measured using the mobil-o-graph (IEM, Germany). Measurement started after a short dialysis interval prior to dialysis and lasted for 24-hours. In a preliminary analysis we describe the results of the first 327 patients with respect to feasibility of central BP measurements.

Results: The mean age of the patients was 65.0±15.1 years. 224 patients were male (69%), 103 patients were female (31%). Out ofIn these 327 patients 16.948 measurements were performed, reflecting an average of 52 measurements per patient. The mean number of measurements was >70% for the whole cohort. Out of the 16.948 measurements 13.069 measurements had a “high quality” and 3.879 had an “acceptable” quality” reflecting a ratio of 3.4. In younger patients <40 years more “high quality” measurements were present (ratio 9.8). This ratio reduced with age (2.6).

Discussion: We examined the feasibility of 24-hour central BP measurement in chronic hemodialysis patients. With >70% performed central BP measurement throughout the 24-hours period this method offers acceptable results for further investigation. The role of different qualities of the determined central measurement needs further investigation especially whether quality of measurements plays a role in the prediction of cardiovascular events.

Journal
Artery Research
Volume-Issue
8 - 4
Pages
151 - 151
Publication Date
2014/11/04
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2014.09.176How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - M. Baumann
AU  - M. Bauhofer
AU  - S. Wassertheurer
AU  - S. Tholen
AU  - C. Hauser
AU  - Y. Suttmann
AU  - A.-L. Hasenau
AU  - U. Heemann
AU  - C. Schmaderer
PY  - 2014
DA  - 2014/11/04
TI  - P8.1 FEASIBILITY OF 24-HOUR CENTRAL BLOOD PRESSURE MEASUREMENTS–THE ISAR HEMODIALYSIS STUDY
JO  - Artery Research
SP  - 151
EP  - 151
VL  - 8
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2014.09.176
DO  - 10.1016/j.artres.2014.09.176
ID  - Baumann2014
ER  -