Artery Research

Volume 8, Issue 4, December 2014, Pages 151 - 151

P7.13 DOES CAROTID ARTERY APPLANATION TONOMETRY CAUSE BAROREFLEX ACTIVATION?

Authors
B. Spronck, T. Delhaas, K. Reesink
University Medical Centre, Maastricht, The Netherlands
Available Online 4 November 2014.
DOI
10.1016/j.artres.2014.09.175How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Introduction: Carotid artery applanation tonometry is widely used to assess carotid-femoral pulse wave velocity and the local carotid artery pressure waveform. However, the substantial pressure applied locally to the carotid artery with applanation tonometry, might evoke a baroreceptor response. This response would lead to changes in heart rate (HR) and blood pressure waveforms, influencing the intended measurements. In this study, we assessed whether carotid applanation tonometry has an influence on HR.

Methods: In 22 hypertensive subjects, HR was assessed during carotid as well as femoral applanation tonometry by continuous finger pulse waveform recording (Nexfin). Subjects were in supine position. Both carotid and femoral acquisitions were measured in alternation and in triplicate. Median averaging over the three measurements was used to obtain a subject’s median HR during carotid as well as femoral tonometry.

Results: HR during carotid tonometry and femoral tonometry was 64.0±9.3bpm and 64.6±9.0bpm, respectively. Difference (carotid-femoral) was −0.7±2.4bpm (p=0.198, two-sided t-test, 95% CI: [−1.7,0.4]bpm). Given a power (1-β) of 0.8 and α=0.05, our study was powered to statistically detect a 1.4bpm HR difference.

Conclusion: We conclude that carotid artery tonometry influences HR by at most 1.4bpm, which appears clinically insignificant.

Journal
Artery Research
Volume-Issue
8 - 4
Pages
151 - 151
Publication Date
2014/11/04
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2014.09.175How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - B. Spronck
AU  - T. Delhaas
AU  - K. Reesink
PY  - 2014
DA  - 2014/11/04
TI  - P7.13 DOES CAROTID ARTERY APPLANATION TONOMETRY CAUSE BAROREFLEX ACTIVATION?
JO  - Artery Research
SP  - 151
EP  - 151
VL  - 8
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2014.09.175
DO  - 10.1016/j.artres.2014.09.175
ID  - Spronck2014
ER  -