Artery Research

Volume 3, Issue 4, December 2009, Pages 164 - 164

P6.02 SIMULTANEOUS MEASUREMENTS OF THE AORTIC AND COMMON CAROTID DISTENSION WAVEFORMS BY MEANS OF ULTRASOUND

Authors
K.G. van den Hengel3, P.J. Brands1, E.M.H. Bosboom2, F.N. van de Vosse3
1Esaote Europe, Maastricht, Netherlands
2Maastricht University Medical Centre, Maastricht, Netherlands
3Eindhoven University of Technology, Maastricht, Netherlands
Available Online 3 December 2009.
DOI
10.1016/j.artres.2009.10.069How to use a DOI?
Abstract
Figure 1

AA and CCA pulse waveform measured during 6 heartbeats in 1 volunteer.

Cardiac and arterial function is reflected in the distension (change in diameter) waveforms of central arteries.

For analyses, commonly the distension waveform of the common carotid artery (CCA) is used, as the CCA is superficial and easily accessible with ultrasound (US). However, the abdominal aorta (AA) is directly connected to the aortic root and a more pronounced influence of cardiovascular diseases on the AA pulse waveform is expected. The aim of this study is to compare the pulse waveforms in AA and CCA.

For this purpose, simultaneous assessment of the distension waveforms in the AA and CCA are performed on three healthy volunteers using two ultrasound scanners with ART.LAB functionality (Picus, Esaote Europe). The two systems are synchronised using ECG triggering. In addition, radial blood pressure is recorded continuously (Colin, USA).

Results show, that AA and CCA distension could reproducibly be measured. The ejection periods of the heart assessed from these pulse waves are equal. The maximum wall velocity is about 2.5 times higher in AA than in CCA. Approximated local blood pressure pulse is higher in AA than in CCA (58 mmHg and 44 mmHg respectively). Local pulse wave velocities, based on the distensibility coefficient, only slightly differ.

Future research will focus on analyzing the differences between both pulse waveforms with a 1D wave propagation model.

Open Access
This is an open access article distributed under the CC BY-NC license.

Download article (PDF)
View full text (HTML)

Journal
Artery Research
Volume-Issue
3 - 4
Pages
164 - 164
Publication Date
2009/12/03
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2009.10.069How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - K.G. van den Hengel
AU  - P.J. Brands
AU  - E.M.H. Bosboom
AU  - F.N. van de Vosse
PY  - 2009
DA  - 2009/12/03
TI  - P6.02 SIMULTANEOUS MEASUREMENTS OF THE AORTIC AND COMMON CAROTID DISTENSION WAVEFORMS BY MEANS OF ULTRASOUND
JO  - Artery Research
SP  - 164
EP  - 164
VL  - 3
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2009.10.069
DO  - 10.1016/j.artres.2009.10.069
ID  - vandenHengel2009
ER  -