Artery Research

Volume 3, Issue 4, December 2009, Pages 162 - 162

P1.08 COMPARING PROXIMAL AND DISTAL OCCLUSION FOR TESTING ENDOTHELIAL FUNCTION USING FOREARM ISCHEMIA – HYPERAEMIA

Authors
P.J. Forcada, S.A. Gonzalez, D. Olano, S. Obregon, C. Castelaro, C. Kotliar
Hospital Universitario Austral, Buenos Aires, Argentina
Available Online 3 December 2009.
DOI
10.1016/j.artres.2009.10.011How to use a DOI?
Abstract

Introduction: There are several approaches to assess endothelial function using forearm ischemia - hyperaemia (FMD). The principal difference is whether flow is stopped in the root of the arm (proximal or P) or the wrist (distal or D). P induces “non pulsatile ischemia”, and D, “pulsatile ischemia”, and the choice based on tolerance.

Aim: Compare the efficacy and tolerability of two different FMD methods.

Methods: Seventeen pts., between 30 and 50 y.o, males, without CV disease or CV drugs were evaluated in the Vascular Lab. FMD was performed at the beginning and at the end of the vascular study (>30minutes apart each one) in a randomized sequence using P or D occlusion and were recorded to be read blinded. Pts. were asked about the tolerance of each method.

Results: Mean age 39+7 y.o, BP 133,4+17 and 82,5+11 mmHg, normal IMT, Plaques (5 subjects, 29%), PWV 10,26+1,8m/seg Aix b −25,7%, Aix Ao 20 %, Vascular score 2,53. Basal diameters humeral artery (mm): P: 3,44+0,5 D: 3,51+0,5 (pNS) Post ischemia diameters (mm): P: 3,63+0,4 D: 3,67+0,4 (p NS). Delta of diameter (%): P: 5,7%+4,8 D: 4,7%+5 (p. NS) (r 0,49p.01, concordant according Bland & Altmann test). About 60% of FMDs were in the same sense and degree and P better tolerated than D.

Conclusions: Although P is better tolerated, there seems to be no significative differences between both methods.

Open Access
This is an open access article distributed under the CC BY-NC license.

Download article (PDF)
View full text (HTML)

Journal
Artery Research
Volume-Issue
3 - 4
Pages
162 - 162
Publication Date
2009/12/03
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2009.10.011How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - P.J. Forcada
AU  - S.A. Gonzalez
AU  - D. Olano
AU  - S. Obregon
AU  - C. Castelaro
AU  - C. Kotliar
PY  - 2009
DA  - 2009/12/03
TI  - P1.08 COMPARING PROXIMAL AND DISTAL OCCLUSION FOR TESTING ENDOTHELIAL FUNCTION USING FOREARM ISCHEMIA – HYPERAEMIA
JO  - Artery Research
SP  - 162
EP  - 162
VL  - 3
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2009.10.011
DO  - 10.1016/j.artres.2009.10.011
ID  - Forcada2009
ER  -