Artery Research

Volume 3, Issue 4, December 2009, Pages 162 - 162

P1.05 ASSESSMENT OF ARTERIAL STIFFNESS IN HYPERTENSION: COMPARISON OF OSCILLOMETRIC (ARTERIOGRAPH), PIEZO-ELECTRONIC (COMPLIOR), AND TONOMETRIC (SPHYGMOCOR) TECHNIQUES

Authors
A. Mahmud, N. Jatoi, J. Feely
Department of Pharmacology & Therapeutics, Trinity College & Hypertension Clinic, St. James’s Hospital, Dublin, Ireland
Available Online 3 December 2009.
DOI
10.1016/j.artres.2009.10.008How to use a DOI?
Abstract

Arterial stiffness, measured as aortic pulse wave velocity (PWV), and wave reflection, measured as augmentation index (AIx) are independent predictors, for total and cardiovascular morbidity and mortality. The aim of this study was to compare a new device, based on oscillometric pressure curves (Arteriograph) which simultaneously measures PWV and AIx to standard techniques for measuring PWV (Complior) and AIx (SphygmoCor) in untreated hypertensive subjects.

We compared PWV and AIx measured using the Arteriograph with corresponding Complior and SphygmoCor measurements in 254 untreated hypertensive patients, age 48±14 (mean±SD) [17 to 85 years].

Arteriograph PWV and AIx were closely related with Complior (r=0.60, P<0.001), and SphygmoCor (r=0.89, P<0.001) respectively. Using stepwise regression analysis, the independent determinants of Arteriograph PWV were age, mean arterial pressure (MAP), heart rate (HR) and gender (R2=0.44p<0.0001) and for AIx; age, weight, MAP, HR and gender (R2=0.65, p<0.0001). The bias between the different techniques was determined by age and gender for PWV and age, body weight, gender, HR and MAP for AIx. Bland-Altman Plots showed that while the techniques were closely related, the limits of agreement were wide.

While Arteriograph values and the determinants of PWV and AIx are in close agreement with corresponding parameters obtained by Complior and SphygmoCor respectively, the techniques are not interchangeable.

Open Access
This is an open access article distributed under the CC BY-NC license.

Download article (PDF)
View full text (HTML)

Journal
Artery Research
Volume-Issue
3 - 4
Pages
162 - 162
Publication Date
2009/12/03
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2009.10.008How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - A. Mahmud
AU  - N. Jatoi
AU  - J. Feely
PY  - 2009
DA  - 2009/12/03
TI  - P1.05 ASSESSMENT OF ARTERIAL STIFFNESS IN HYPERTENSION: COMPARISON OF OSCILLOMETRIC (ARTERIOGRAPH), PIEZO-ELECTRONIC (COMPLIOR), AND TONOMETRIC (SPHYGMOCOR) TECHNIQUES
JO  - Artery Research
SP  - 162
EP  - 162
VL  - 3
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2009.10.008
DO  - 10.1016/j.artres.2009.10.008
ID  - Mahmud2009
ER  -