Comparasion Between Pooled Sera Material and Commercial Serum on the Accuracy of Triglyceride Check
- DOI
- 10.2991/ahsr.k.211026.066How to use a DOI?
- Keywords
- triglyceride, pooled sera, commercial serum
- Abstract
The increase in cases of dyslipidemia every year, requires the Clinical Chemistry laboratory to carry out quality control which is influenced by the assessment of precision and accuracy. These measurements are used with the control material. The laboratory of RSU Mayjen HA Thalib Kerinci uses commercial serum control materials as control materials that are used daily in the triglycerides check, and has never used pooled sera. In fact, there are several advantages to using pooled sera as a control material. The reseach is an analytic survey research with a comparative study method. The sampling technique used was purposive sampling. Data collected by using an observation sheet. Data were processed in computerized with univariate analysis and bivariate analysis using independent t-test. The results showed that the average value of the triglyceride check by using Pooled Sera control material was 94.67 mg / dL with a standard deviation of 2.52, the coefficient of variance was 2.66%. While the test results of triglycerides with Commercial Serum control material was 79.13 mg / dL with a Standard Deviation of 3.57, the coefficient of variance is 4.51%. It was concluded that there was a significant difference between the triglyceride check with Pooled Sera and Commercial Serum materials. It is recommended that the development of medical laboratory technology in hospitals, making this research to be a reference in educational institutions, and for further research on other parameters, including Pooled Sera and other Serum materials.
- Copyright
- © 2021, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Wiwit Nia Anggra AU - Ibrahim AU - Rahmi Novita Yusuf PY - 2021 DA - 2021/10/28 TI - Comparasion Between Pooled Sera Material and Commercial Serum on the Accuracy of Triglyceride Check BT - Proceedings of the 2nd Syedza Saintika International Conference on Nursing, Midwifery, Medical Laboratory Technology, Public Health, and Health Information Management (SeSICNiMPH 2021) PB - Atlantis Press SP - 330 EP - 334 SN - 2468-5739 UR - https://doi.org/10.2991/ahsr.k.211026.066 DO - 10.2991/ahsr.k.211026.066 ID - Anggra2021 ER -