Study on treatment of ultra-high concentration phosphorus-containing wastewater
- DOI
- 10.2991/rsete.2013.121How to use a DOI?
- Keywords
- lime electrolysis Phosphorus removal
- Abstract
An efficient combined treatment process, lime-electrolysis was developed to treat the Ultra-high concentration phosphorus-containing Wastewater. The experimental results show that the removal rates of COD and TP are 86.4%, 69.9%,respectively. The results indicated that the optimal conditions are: lime dosage was 2g, pH 8.5,mixing rate 2.5(equivalent units)and reaction time 20min, sedimentation time 10min; using the soluble iron plate and carbon rod as electrode plate, electrolysis pH 7, electric current 0.4 A, reaction time 80 min, exchange electrode reaction 2min per 12min. The biodegradability of the wastewater was improved evidently. This combined process provides instructive example for efficient treatment of Ultra-high concentration phosphorus-containing Wastewater.
- Copyright
- © 2013, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Qi Peishi AU - Yao Xiaoran AU - Liu Yunzhi PY - 2013/08 DA - 2013/08 TI - Study on treatment of ultra-high concentration phosphorus-containing wastewater BT - Proceedings of the 2013 the International Conference on Remote Sensing, Environment and Transportation Engineering (RSETE 2013) PB - Atlantis Press SP - 498 EP - 501 SN - 1951-6851 UR - https://doi.org/10.2991/rsete.2013.121 DO - 10.2991/rsete.2013.121 ID - Peishi2013/08 ER -