Analysis about Risk Changes before and After Inspection of 23 Storage Tanks and Research on the Inspection Strategy
- DOI
- 10.2991/msmee-17.2017.59How to use a DOI?
- Keywords
- Oil Storage Tank, Risk Evaluation, Inspection Strategy, Case
- Abstract
Inspection of storage tanks has been taken less seriously over past years, as not required by laws. Therefore, projects adopting risk evaluation technology of atmospheric-pressure storage tanks are rarely seen. Characterized by large volume and high risks, hazardous chemicals often lead to serious accidents. This paper evaluates risks of 23 atmospheric-pressure storage tanks of 100 thousand m3 of a storage house. Supposing the storage house implemented inspection within 5 years or 10 years, this paper studies risk changes before and after the inspection. It puts forward an inspection strategy to guarantee long term safety of storage tanks according to the risk analysis outcome.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Zhou Fang AU - Shu Xing AU - Qi Chen AU - Gongtian Shen AU - Yanxiu Zhao PY - 2017/05 DA - 2017/05 TI - Analysis about Risk Changes before and After Inspection of 23 Storage Tanks and Research on the Inspection Strategy BT - Proceedings of the 2017 2nd International Conference on Materials Science, Machinery and Energy Engineering (MSMEE 2017) PB - Atlantis Press SP - 281 EP - 285 SN - 2352-5401 UR - https://doi.org/10.2991/msmee-17.2017.59 DO - 10.2991/msmee-17.2017.59 ID - Fang2017/05 ER -