Quantitative Analysis on Heat Storage Capacity in Steam and Metal of Ultra-Supercritical Once-Through Boiler
- DOI
- 10.2991/mseee-18.2018.41How to use a DOI?
- Keywords
- once-through boiler, ultra-supercritical and subcritical, heat storage coefficient.
- Abstract
As an increasing number of power plants are engaged in grid peaking operations, the utility boiler working condition varies frequently and violently, which demands a more flexible and accurate control system. In present investigation, a model measuring heat storage capacity in steam and metal with operating data of 1000MW unit is proposed. In the scope of investigation, calculated result shows the overall heat coefficient in subcritical working condition is 27% more than that in supercritical condition. The heat storage coefficient distribution of steam and metal varies with the change of working condition, and detailed information is exhibited. Moreover, reheat steam system is also in the scope of present investigation which is rarely reported.
- Copyright
- © 2018, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Tianyu Zhang AU - Lele Ma AU - Xi Zhao AU - Chengyong Liu AU - Zhenning Zhao PY - 2018/08 DA - 2018/08 TI - Quantitative Analysis on Heat Storage Capacity in Steam and Metal of Ultra-Supercritical Once-Through Boiler BT - Proceedings of the 2nd International Conference on Material Science, Energy and Environmental Engineering (MSEEE 2018) PB - Atlantis Press SP - 231 EP - 236 SN - 2352-5401 UR - https://doi.org/10.2991/mseee-18.2018.41 DO - 10.2991/mseee-18.2018.41 ID - Zhang2018/08 ER -