Simulation and Analysis of Loss-of-Coolant Accident in Cold Leg of PWR Based on ATHLET and SIMIS
Authors
Tianxiao Li, Wenping Zhou, Wei Sheng, Fan Li, Weizhe Li, Yunping Cai, Guoxiu Qin, Xuesong Zhang
Corresponding Author
Tianxiao Li
Available Online October 2017.
- DOI
- 10.2991/meici-17.2017.72How to use a DOI?
- Keywords
- PWR; Cold leg; Small break; ATHLET; SIMIS
- Abstract
An accident safety analysis of small break loss of coolant is needed in order to avoiding the loss of coolant accident due to inadequate cooling in the reactor core and the leak of radioactive after the small break in primary circuit. We analyze the small break loss of coolant accident in cold leg of PWR primary coolant system by using Daya Bay 1000 MW nuclear power plant simulation system. Then we compare the result with another result which simulated by the software named ATHLET and verify the accuracy about simulation system.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Tianxiao Li AU - Wenping Zhou AU - Wei Sheng AU - Fan Li AU - Weizhe Li AU - Yunping Cai AU - Guoxiu Qin AU - Xuesong Zhang PY - 2017/10 DA - 2017/10 TI - Simulation and Analysis of Loss-of-Coolant Accident in Cold Leg of PWR Based on ATHLET and SIMIS BT - Proceedings of the 7th International Conference on Management, Education, Information and Control (MEICI 2017) PB - Atlantis Press SP - 380 EP - 385 SN - 1951-6851 UR - https://doi.org/10.2991/meici-17.2017.72 DO - 10.2991/meici-17.2017.72 ID - Li2017/10 ER -