Multiple Setup Model for Coiling Temperature Control in Hot Strip Mill
- DOI
- 10.2991/meees-18.2018.22How to use a DOI?
- Keywords
- Temperature Control; Coiling Temperature; Hot Strip Mill; Feed Forward; TVD curve.
- Abstract
The coiling temperature control method of a typical hot strip mill was investigated. Based on Time-Velocity-Distance (TVD) curve, the generation of velocity deviation between the calculated and measured was present and discussed in detail. To deal with the deviation of velocity, the main cooling zone was divided into two parts by the medium pyrometer, and the feed forward model was triggered under finishing pyrometer and medium pyrometer respectively for one strip segment. The temperature deviation of feed forward setup under finishing pyrometer could be corrected by the feed forward setup under medium pyrometer effectively. Application results indicated that the control precision of coiling temperature on different steel grades had been improved to varying degrees, and the highest point was up to nearly 4%.
- Copyright
- © 2018, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Xudong Li AU - Shuzhi Wang AU - Fang Xu AU - Lijie Dong AU - Bo Gong AU - Changli Zhang AU - Ziying Liu AU - Fengqin Wang PY - 2018/05 DA - 2018/05 TI - Multiple Setup Model for Coiling Temperature Control in Hot Strip Mill BT - Proceedings of the 2018 International Conference on Mechanical, Electrical, Electronic Engineering & Science (MEEES 2018) PB - Atlantis Press SP - 113 EP - 117 SN - 2352-5401 UR - https://doi.org/10.2991/meees-18.2018.22 DO - 10.2991/meees-18.2018.22 ID - Li2018/05 ER -