Proceedings of the 2015 International Conference on Materials, Environmental and Biological Engineering

Leakage Causes Analysis on a Boiler Enclosure Wall Superheater

Authors
Weiyong Li, Yaofang He, Xin Guan, Yanjun Meng
Corresponding Author
Weiyong Li
Available Online April 2015.
DOI
10.2991/mebe-15.2015.48How to use a DOI?
Keywords
Leakage; superheater; weld parameter
Abstract

The leakage reasons for a boiler enclosure wall superheater were discussed based on experimental results of macro fracture observation, chemical composition analysis, metallurgical microstructure examination, SEM and EDS analysis. It was presumed that weld flaw firstly formed due to large weld process parameters, then propagated under long period fatigue stress and developed to penetrated crack, leading to final leakage. It was suggested that boiler supervision and four-tube inspection should be enhanced.

Copyright
© 2015, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2015 International Conference on Materials, Environmental and Biological Engineering
Series
Advances in Engineering Research
Publication Date
April 2015
ISBN
978-94-62520-57-8
ISSN
2352-5401
DOI
10.2991/mebe-15.2015.48How to use a DOI?
Copyright
© 2015, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Weiyong Li
AU  - Yaofang He
AU  - Xin Guan
AU  - Yanjun Meng
PY  - 2015/04
DA  - 2015/04
TI  - Leakage Causes Analysis on a Boiler Enclosure Wall Superheater
BT  - Proceedings of the 2015 International Conference on Materials, Environmental and Biological Engineering
PB  - Atlantis Press
SP  - 201
EP  - 204
SN  - 2352-5401
UR  - https://doi.org/10.2991/mebe-15.2015.48
DO  - 10.2991/mebe-15.2015.48
ID  - Li2015/04
ER  -