Analysis for the Fault Caused by Two Different Formats of Bus Data Delivery
Authors
Rui Shen, Hengxin Cai
Corresponding Author
Rui Shen
Available Online July 2015.
- DOI
- 10.2991/lemcs-15.2015.325How to use a DOI?
- Keywords
- Electronic programmable controller; Data transfer format; RS429; RS422
- Abstract
The electronic programmable controller of a fighter can receive the RS429 signal from atmospheric system, meanwhile it can transform the signal to RS422, but the indicator light indicates abnormal. The fault caused by the electronic programmable controller is found when it transforms the signal from the atmospheric system to the wrong format. The data formats of the RS429 and the RS422 are analyzed, the root cause and a solution to this problem are derived.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Rui Shen AU - Hengxin Cai PY - 2015/07 DA - 2015/07 TI - Analysis for the Fault Caused by Two Different Formats of Bus Data Delivery BT - Proceedings of the International Conference on Logistics, Engineering, Management and Computer Science PB - Atlantis Press SP - 1625 EP - 1627 SN - 1951-6851 UR - https://doi.org/10.2991/lemcs-15.2015.325 DO - 10.2991/lemcs-15.2015.325 ID - Shen2015/07 ER -