- Abstract
The monolithic cylindrical fused silica resonator is the critical component of a cylindrical resonator gyroscope, and the Q factor is the key parameter to evaluate the performance of a cylindrical resonator. In this paper, a non-contact measurement system based on acoustic excitation and laser Doppler detection was proposed to measure the Q factor of the cylindrical resonator. Two measurement methods (i.e. the frequency response method and the ring-down time method) were proposed, and the testing procedure was carefully designed. The reliability and stability of two methods were verified by simulations and experiments. Results showed that the ring-down time method can be applied to measure a wide range of Q factors with good repeatability, while the frequency response method is applicable only in low Q situations.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Dongya Wang AU - Yao Pan AU - Suyong Wu AU - Hongchang Zhao AU - Tianliang Qu AU - Jianxun Tang PY - 2016/10 DA - 2016/10 TI - Non-contact Measurement of Quality Factor for Monolithic Cylindrical Fused Silica Resonators BT - Proceedings of the 2016 Joint International Information Technology, Mechanical and Electronic Engineering PB - Atlantis Press SP - 17 EP - 23 SN - 2352-5401 UR - https://doi.org/10.2991/jimec-16.2016.4 DO - 10.2991/jimec-16.2016.4 ID - Wang2016/10 ER -