Experimental Study on the Single Factor of Hydrogen Peroxide for the Degradation of Aniline
- DOI
- 10.2991/ism3e-15.2015.30How to use a DOI?
- Abstract
This paper wastewater aniline reaction solution, the first reaction was added H2O2 degradation, changing the initial concentration of aniline were simulated wastewater, amount of H2O2, reaction time, pH value, investigate the effect of aniline degradation efficiency, the experimental results show : degradation rate of aniline in the 5.0mg/L-30.0mg/L concentration range as the initial concentration of aniline wastewater temperature increased, the pH value of 6:00, aniline degradation rate could reach 82.7%, with the H2O2 increased dosage, increasing the lead degradation of aniline wastewater, and then decreased significantly, with time, the degradation rate of aniline gradually increased, reaching 79.2% in 40min time.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Yongguang Bi AU - Minxia Huang AU - Shiting Deng AU - Hong Yu AU - Xue wei Chen AU - Xuemei Liu AU - Hai lan Huang PY - 2015/11 DA - 2015/11 TI - Experimental Study on the Single Factor of Hydrogen Peroxide for the Degradation of Aniline BT - Proceedings of the 2015 International Symposium on Material, Energy and Environment Engineering PB - Atlantis Press SP - 114 EP - 116 SN - 2352-5401 UR - https://doi.org/10.2991/ism3e-15.2015.30 DO - 10.2991/ism3e-15.2015.30 ID - Bi2015/11 ER -