Experimental study on optimization of water reducer in pumping concrete
- DOI
- 10.2991/isaeece-17.2017.15How to use a DOI?
- Keywords
- water reducer; naphthalene-based type; polycarboxylate-based type; pumping concrete
- Abstract
The different water reducers have different suitability and different influence of performance with concrete mixture. Combined with the engineering practice, 3 kinds of naphthalene-based water reducer (NSR) and 4 kinds of polycarboxylate-based water reducer (PC) were selected as the objects. The saturation dosage of water reducers was determined by single factor test. Using the concrete standard mixture in the saturated dosage of the water reducer, the pumping concrete slump loss, gas loss, bleeding rate, setting time and separation properties about the 7 kinds of water reducers under the state of the coarse aggregate saturated surface dried and air dried were tested in order to select 4 of the adaptability of water reducer. By testing 4 kinds of water reducers, it's shown that the performance of concrete mixed with water reducer is optimal after 60 minutes.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Qiansheng Yuan PY - 2017/03 DA - 2017/03 TI - Experimental study on optimization of water reducer in pumping concrete BT - Proceedings of the 2017 2nd International Symposium on Advances in Electrical, Electronics and Computer Engineering (ISAEECE 2017) PB - Atlantis Press SP - 79 EP - 84 SN - 2352-5401 UR - https://doi.org/10.2991/isaeece-17.2017.15 DO - 10.2991/isaeece-17.2017.15 ID - Yuan2017/03 ER -