Quality evaluation of protective film based on optical coherence tomography
Authors
Jing Feng, Guozhong Liu, Shenjia Zhang
Corresponding Author
Jing Feng
Available Online March 2015.
- DOI
- 10.2991/iiicec-15.2015.441How to use a DOI?
- Keywords
- Quality evaluation of protective film; Spectral-Domain Optical Coherence Tomography; 3D visualization; non-destructive testing
- Abstract
In order to evaluate the quality of the protective films, we built a Spectral-Domain Optical Coherence Tomography System. To get the 2D and 3D image of normal materials and defective materials, and the quantitative analysis has been done. Compared with the parameters provided by the manufacturer, the results of this method has a smaller detection error, higher precision and its results are 3D visualization. An optical non-destructive testing method with high precision and 3D visualization results has been provided to evaluate the quality of the protective films.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Jing Feng AU - Guozhong Liu AU - Shenjia Zhang PY - 2015/03 DA - 2015/03 TI - Quality evaluation of protective film based on optical coherence tomography BT - Proceedings of the 2015 International Industrial Informatics and Computer Engineering Conference PB - Atlantis Press SP - 2020 EP - 2023 SN - 2352-538X UR - https://doi.org/10.2991/iiicec-15.2015.441 DO - 10.2991/iiicec-15.2015.441 ID - Feng2015/03 ER -