Proceedings of the 2016 International Forum on Mechanical, Control and Automation (IFMCA 2016)

Water flow simulation and emergent treatment procedure of water supply channel without control gate

Authors
Ke Kong, Kun Wang, Zhenghe Xu
Corresponding Author
Ke Kong
Available Online March 2017.
DOI
10.2991/ifmca-16.2017.82How to use a DOI?
Keywords
water supply channel; simulation; Mike11; control gate; emergent treatment
Abstract

It is difficult for reservoirs to guarantee their main water supply aims when the water demands are tremendous and the control gats in its water supply channel are inavailable. In this papper three monitor points are set in the start, the middle and the end of the channel of the Jinxiuchuan reservoir. The collected monitoring data are input into Mike11 to simulate the procedure of water flow procedure in this channel during the irrigation period when the rural water demand and municipal water demand are conflict. The relationship of water amount achieved by the municipal users and the water levels along the channel are analyzed; the threshold values of water supply risk are obtained, so that the emergent treatment program is made, which can provide technology support for reservoir's water supply decision.

Copyright
© 2017, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2016 International Forum on Mechanical, Control and Automation (IFMCA 2016)
Series
Advances in Engineering Research
Publication Date
March 2017
ISBN
978-94-6252-307-4
ISSN
2352-5401
DOI
10.2991/ifmca-16.2017.82How to use a DOI?
Copyright
© 2017, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Ke Kong
AU  - Kun Wang
AU  - Zhenghe Xu
PY  - 2017/03
DA  - 2017/03
TI  - Water flow simulation and emergent treatment procedure of water supply channel without control gate
BT  - Proceedings of the 2016 International Forum on Mechanical, Control and Automation (IFMCA 2016)
PB  - Atlantis Press
SP  - 537
EP  - 541
SN  - 2352-5401
UR  - https://doi.org/10.2991/ifmca-16.2017.82
DO  - 10.2991/ifmca-16.2017.82
ID  - Kong2017/03
ER  -