Study On The Influence Of FC Evaporator Structure On The Internal Flow Field
- DOI
- 10.2991/ifeesm-17.2018.202How to use a DOI?
- Keywords
- FC Forced circulation evaporator;Internal flow field;Finite element analysis; Multiphase flow
- Abstract
Take the structure of the FC evaporator for desulfurization wastewater from power plant as the research object establish model of the finite element analysis and the internal flow simulation is carried out. Compare the characteristics of the flow field in the evaporator with the different structure parameters, and study the particle size distribution. The results show that the angle of the inlet tube and the angle of the discharge outlet can affect the local flow field in the evaporator, thus affecting the crystallization process. By adjusting the above Angle and optimizing the internal flow field, the particle phase can be fully mixed to avoid the solid phase segregation.
- Copyright
- © 2018, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Chong Zhao AU - Ruozheng Li AU - Peilin Zhang AU - Jilin Teng AU - Ying Tian AU - Wenming Ma PY - 2018/02 DA - 2018/02 TI - Study On The Influence Of FC Evaporator Structure On The Internal Flow Field BT - Proceedings of the 2017 3rd International Forum on Energy, Environment Science and Materials (IFEESM 2017) PB - Atlantis Press SP - 1102 EP - 1108 SN - 2352-5401 UR - https://doi.org/10.2991/ifeesm-17.2018.202 DO - 10.2991/ifeesm-17.2018.202 ID - Zhao2018/02 ER -