Numerical simulation of thermal performance of different frost-resisting measures for the tunnel lining in cold region
- DOI
- 10.2991/ifeesm-17.2018.52How to use a DOI?
- Keywords
- tunnel; lining; temperature field; thermal performance
- Abstract
Frost-resisting problem is important for the tunnel in cold region, and thus some thermal protective measure are necessary in order to avoid potential frost. With the development of land transport, tunnels plays an important role in the improvement of land transportation, so it is urgent to prevent the freezing and thawing of tunnel in cold region. In this paper, the temperature field of Jinzhangzi tunnel is chosen as a target project, and corresponding three protective measure are taken into account. There are four cases are considered respectively. Including the unprotected, the active heating system, passive thermal insulation system and hybrid thermal protective system. Especially, the hybrid thermal protective system maybe the cost efficient.
- Copyright
- © 2018, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Chengjin Ma AU - Runlin Yang AU - Shuai Zhang PY - 2018/02 DA - 2018/02 TI - Numerical simulation of thermal performance of different frost-resisting measures for the tunnel lining in cold region BT - Proceedings of the 2017 3rd International Forum on Energy, Environment Science and Materials (IFEESM 2017) PB - Atlantis Press SP - 275 EP - 279 SN - 2352-5401 UR - https://doi.org/10.2991/ifeesm-17.2018.52 DO - 10.2991/ifeesm-17.2018.52 ID - Ma2018/02 ER -