A High Precision Stray-immune Weak Capacitance Measurement System for Gas-solid Two-phase Flows Detection
- DOI
- 10.2991/iea-15.2015.36How to use a DOI?
- Keywords
- capacitance measurement; weak capacitance; direct digital synthesizer; stray-immune.
- Abstract
A novel weak capacitance measurement system is proposed to measure the gas-solid two-phase flows. The system is mainly consist of capacitance sensor, Micro-programmed Control Unit (MCU), Direct Digital Synthesizer (DDS), operational amplifier, analogue multiplier and low-pass filter. Since the stray capacitance is much larger than the variation of measured capacitance, the stray capacitance should be eliminate by the measurement system. The experimental results show that the system meets the application requirement, and has good linearity, high measurement accuracy and stray-immune. The result of the percentage error is about 0.6% and the non-linear error is less than 1.5%. The sampling rate which is related to the frequency of the signal generator and the MCU clock can reach 500 kps.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Song Feihu AU - Hong Hui AU - Liu Shuai PY - 2015/09 DA - 2015/09 TI - A High Precision Stray-immune Weak Capacitance Measurement System for Gas-solid Two-phase Flows Detection BT - Proceedings of the AASRI International Conference on Industrial Electronics and Applications (2015) PB - Atlantis Press SP - 143 EP - 146 SN - 2352-5401 UR - https://doi.org/10.2991/iea-15.2015.36 DO - 10.2991/iea-15.2015.36 ID - Feihu2015/09 ER -