Study on Bearing Capacity of the Connection between Concrete-Filled Twin Steel Tubes Column and Steel Beam
- DOI
- 10.2991/icsmim-15.2016.201How to use a DOI?
- Keywords
- CFTST column; steel beam;; vertical stiffener; anchorage plate; bearing capacity
- Abstract
This study evaluates the bearing capacity of a new type of connection between the concrete-filled twin steel tubes (CFTST) column and steel beams. The formation and feature of the connection were described. The tensile force from girder flange is mainly transferred by vertical stiffener and anchorage plate according to the analysis of experiment and finite element simulation, so the model of tensile beam flange was proper to analyze the bearing capacity of the joint. Theoretical formula to calculate the load-bearing capability of this joint was derived. Compared with experimental results calculated results were basically correct but conservative. Theoretical formula to calculate the load-bearing capability of this joint was derived from the model of tensile beam flange. Compared with experimental results, calculated results with the error of 2.16~4.14%, were basically correct but conservative. All the research results can provide a basis for its further research and application in practice.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Yufen Zhang AU - Qiang Wang PY - 2016/01 DA - 2016/01 TI - Study on Bearing Capacity of the Connection between Concrete-Filled Twin Steel Tubes Column and Steel Beam BT - Proceedings of the 2015 4th International Conference on Sensors, Measurement and Intelligent Materials PB - Atlantis Press SP - 1096 EP - 1102 SN - 2352-538X UR - https://doi.org/10.2991/icsmim-15.2016.201 DO - 10.2991/icsmim-15.2016.201 ID - Zhang2016/01 ER -