Fluid-induced Vibrations Test of Hydraulic Plane Gate for Different Conditions
- DOI
- 10.2991/icsmim-15.2016.199How to use a DOI?
- Keywords
- plane gate; fluid-induced vibration; PIV; flowing measurement
- Abstract
The hydraulic test model was built to investigate the fluid-induced vibration of plane gate by changing the gate opening and flow rate respectively. The flow field near the gate was measured with the PIV system while the gate structure was measured with 8 channels high speed vibration acquisition system In the experiments, the dynamic distribution characteristics of the flow field around gate and dynamics parameters of the gate structure were measured. The results show that the gate opening and flow rate affect the flow-induced vibration of gate directly. Gate vibration shows asymmetric and aperiodic coupling vibration characteristics. When the flow field interacts with gate, the flow field near the gate is further disturbed. The changes of the corresponding flow boundary conditions result in the downstream fluid showing complex turbulent motion.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Tingting Yang AU - Shihua He AU - Chunying Shen AU - Qi Yang PY - 2016/01 DA - 2016/01 TI - Fluid-induced Vibrations Test of Hydraulic Plane Gate for Different Conditions BT - Proceedings of the 2015 4th International Conference on Sensors, Measurement and Intelligent Materials PB - Atlantis Press SP - 1083 EP - 1089 SN - 2352-538X UR - https://doi.org/10.2991/icsmim-15.2016.199 DO - 10.2991/icsmim-15.2016.199 ID - Yang2016/01 ER -