Exergy Analysis of Air-source Heat Pump Water Heater
- DOI
- 10.2991/icsmim-15.2016.37How to use a DOI?
- Keywords
- air source heat pump water heater system exergy efficiency exergy loss coefficient
- Abstract
Based on the exergy analysis model and the data of an ASHPWH system,exergy analysis of the system was carried out,and the way was discussed to reduce exergy loss.The exergy efficiency of the system was 43.7%,and the exergy loss coefficient of the compressor was the largest in the system,accounting for 26.12%.then, the exergy loss coefficient of the expansion valve, the condenser and the evaporator account for 14.15%,9.82%and 6.21% respectively.The key components to improve the exergy efficiency were compressor and expansion valve,and the join control of electronic expansion valve and variable frequency compressor may be a feasible way to improve improve exergy efficiency.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Bingjie Mi AU - Qinghai Luo AU - Guojie Chen PY - 2016/01 DA - 2016/01 TI - Exergy Analysis of Air-source Heat Pump Water Heater BT - Proceedings of the 2015 4th International Conference on Sensors, Measurement and Intelligent Materials PB - Atlantis Press SP - 197 EP - 202 SN - 2352-538X UR - https://doi.org/10.2991/icsmim-15.2016.37 DO - 10.2991/icsmim-15.2016.37 ID - Mi2016/01 ER -