Frequency conversion control method for reducing switching loss of inverter
- DOI
- 10.2991/icsma-16.2016.129How to use a DOI?
- Keywords
- Inverter, frequency conversion, loss optimization, dual Buck converter.
- Abstract
Inverter with sinusoidal pulse width modulation in the operation of certain moments of the inductor current ripple is smaller, still maintain a switch with higher frequency, which will undoubtedly increase the loss of inverter unnecessarily. In this paper, a new control method of the inverter switching frequency is proposed. In this method, , inverter switching frequency is modified, while inductor current ripple peak to peak value is kept constant, in order to reduce the switching loss of the inverter power devices. Small signal modeling and analysis show that the introduction of inverter switching frequency control will not affect the steady-state and dynamic performance of the loop control system. The effectiveness of the proposed control method is verified by both simulation and experiment.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Shixian Li AU - Fanghua Zhang PY - 2016/12 DA - 2016/12 TI - Frequency conversion control method for reducing switching loss of inverter BT - Proceedings of the 2016 4th International Conference on Sensors, Mechatronics and Automation (ICSMA 2016) PB - Atlantis Press SP - 747 EP - 752 SN - 1951-6851 UR - https://doi.org/10.2991/icsma-16.2016.129 DO - 10.2991/icsma-16.2016.129 ID - Li2016/12 ER -