Experimental and Simulant Study on the Ground Source Heat Pump in Winter of Hefei
Authors
Huizeng Li, Ning Hu, Chongda Jiang, Zhengling Hu, Jinwei Ma, Yanping Wang
Corresponding Author
Huizeng Li
Available Online April 2016.
- DOI
- 10.2991/icseee-15.2016.108How to use a DOI?
- Keywords
- ground source, heat pump,u-shaped, heat exchanger
- Abstract
Based on the operation of a Ground Source Heat Pump (GSHP) in Hefei, the heat exchange of the 100m depth vertical u-shaped pipe buried in the ground was analyzed, and the heat transfer performance, efficiency of the system and temperature variation of the ground were studied experimentally under the typical climate in Hefei. Temperature changes of the field near the heat exchanger after 8h and 24h were analyzed by numerical simulation. Results show that the system has a good performance in winter.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Huizeng Li AU - Ning Hu AU - Chongda Jiang AU - Zhengling Hu AU - Jinwei Ma AU - Yanping Wang PY - 2016/04 DA - 2016/04 TI - Experimental and Simulant Study on the Ground Source Heat Pump in Winter of Hefei BT - Proceedings of the 2015 4th International Conference on Sustainable Energy and Environmental Engineering PB - Atlantis Press SP - 630 EP - 635 SN - 2352-5401 UR - https://doi.org/10.2991/icseee-15.2016.108 DO - 10.2991/icseee-15.2016.108 ID - Li2016/04 ER -