Research on Optimal Adjustment Test for SCR Denitrification System in Coal-fired Power Plant
Authors
Ke Liu, Meng Zhang, Hai-Chao Wang, Li-Meng Zhang, Fan-Jun Hou, Qing-Chuan Zhao
Corresponding Author
Ke Liu
Available Online December 2016.
- DOI
- 10.2991/icsd-16.2017.82How to use a DOI?
- Keywords
- SCR; Denitrification system; Adjustment test; Ammonia escape
- Abstract
We present an effective optimal adjustment test method for SCR denitrification device. The decrease of catalyst activity in local regions can lead to non-uniformity of NOx concentration and augmentation of slipped ammonia around outlet of SCR device. In this case, we introduce a two-step adaptive adjustment method to minimize the concentration of slipped ammonia meanwhile ensures the NOx emission concentration around outlet of SCR within standard range.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Ke Liu AU - Meng Zhang AU - Hai-Chao Wang AU - Li-Meng Zhang AU - Fan-Jun Hou AU - Qing-Chuan Zhao PY - 2016/12 DA - 2016/12 TI - Research on Optimal Adjustment Test for SCR Denitrification System in Coal-fired Power Plant BT - Proceedings of the 2nd 2016 International Conference on Sustainable Development (ICSD 2016) PB - Atlantis Press SP - 366 EP - 369 SN - 2352-5401 UR - https://doi.org/10.2991/icsd-16.2017.82 DO - 10.2991/icsd-16.2017.82 ID - Liu2016/12 ER -