Analysis and Calculation of Lighting Strength in the Annur Building Jalan Purnawirawan Bandar Lampung

Authors
A. Dzakwan1, *, S. Suharno2, S. Sri Ratna3, Endro P. Wahono4, M. Usman5
1Environmental Engineering Study Program, Faculty of Engineering, University of Lampung, Bandar Lampung, Lampung, Indonesia, 35145
2Geophysical Engineering Study Program, Faculty of Engineering, University of Lampung, Bandar Lampung, Lampung, Indonesia, 35145
3Electrical Engineering Study Program, Faculty of Engineering, University of Lampung, Bandar Lampung, Lampung, Indonesia, 35145
4Civil Engineering Study Program, Faculty of Engineering, University of Lampung, Bandar Lampung, Lampung, Indonesia, 35145
5Mathematics Study Program, Faculty of Mathematics and Natural Sciences, University of Lampung, Bandar Lampung, Lampung, Indonesia, 35145
*Corresponding author. Email: dzakwan@eng.unila.ac.id
Corresponding Author
A. Dzakwan
Available Online 2 August 2024.
DOI
10.2991/978-94-6463-475-4_25How to use a DOI?
Keywords
SNI standards; Strong lighting; equality; Room Comfort Equations and Building comfort equations
Abstract

The ideal lighting system is a lighting system that creates a comfortable feeling when felt in the room. The lighting strength recommended by SNI standards (Indonesian National Standards) consists of 150 lux (low), 200 lux (somewhat low), 250 lux (medium), 300 lux (somewhat high) and 350 lux (high). The method in this research is to compare the lighting (E) at each specific position in rooms R1, R2 and R3 with SNI lighting standards, so that the average ratio of lighting parameters in each room is obtained which is called the room comfort equation (RCE) and then adding them up for each space throughout the building which is called the building comfort equation (BCE). The parameter ratio is P1 = E1/ ESNI, for R1 and R2 both are meeting rooms with SNI ESNI standards = 300 lux and for R3 (parking space) it is P3 = E3/ESNI, with SNI I lighting standards = 150. The ideal prices for all three are at intervals 1 – 0.01 < P3 < 1 + 0.01. The results of the calculations are the ratio of indoor lighting parameters of 0.260, 0.108 and 0.521, which is called the room comfort equation (RCE). in the building (BCE) with the Pt limit condition at interval 3 – 0.03 < Pt < 1 + 0.03. Because the total lighting ratio Pt for the three rooms is not in the interval 2.97 < Pt < 3.03, the Annur Center building authorities need to adjust the lighting strength to achieve ideal conditions.

Copyright
© 2024 The Author(s)
Open Access
Open Access This chapter is licensed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/), which permits any noncommercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made.

Download article (PDF)

Volume Title
Proceedings of the 1st International Conference on Industry Science Technology and Sustainability (IConISTS 2023)
Series
Advances in Engineering Research
Publication Date
2 August 2024
ISBN
978-94-6463-475-4
ISSN
2352-5401
DOI
10.2991/978-94-6463-475-4_25How to use a DOI?
Copyright
© 2024 The Author(s)
Open Access
Open Access This chapter is licensed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/), which permits any noncommercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made.

Cite this article

TY  - CONF
AU  - A. Dzakwan
AU  - S. Suharno
AU  - S. Sri Ratna
AU  - Endro P. Wahono
AU  - M. Usman
PY  - 2024
DA  - 2024/08/02
TI  - Analysis and Calculation of Lighting Strength in the Annur Building Jalan Purnawirawan Bandar Lampung
BT  - Proceedings of the 1st International Conference on Industry Science Technology and Sustainability (IConISTS 2023)
PB  - Atlantis Press
SP  - 289
EP  - 302
SN  - 2352-5401
UR  - https://doi.org/10.2991/978-94-6463-475-4_25
DO  - 10.2991/978-94-6463-475-4_25
ID  - Dzakwan2024
ER  -