Center aspirated ejector suction performance of numerical simulation
- DOI
- 10.2991/icmmse-16.2016.65How to use a DOI?
- Keywords
- CFD simulation technique, Compound flotation machine, Injector, Suction
- Abstract
Article briefly describes the application of CFD simulation technique and experimental validation in the development, improvement and optimization of flotation machine, meanwhile the paper designs an injector used for compound flotation machine according to working principle. The conical injector with shrinking angle ?=13° and the straight conical injector with shrinking angle ?=13° and length-diameter ratio l/d=3 are simulated by fluid dynamics software fluent. The paper analyzes emphatically the suction property of the two kinds of injector under the condition of different distance from the suction pipe to outlet. The results show that the suction property of the straight conical injector is superior to the conical injector. The suction property is the best for straight cone injector when distance between suction pipe and outlet within 14~22 mm.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Jinbo Zhu PY - 2016/03 DA - 2016/03 TI - Center aspirated ejector suction performance of numerical simulation BT - Proceedings of the 2016 International Conference on Mechanics, Materials and Structural Engineering PB - Atlantis Press SP - 391 EP - 396 SN - 2352-5401 UR - https://doi.org/10.2991/icmmse-16.2016.65 DO - 10.2991/icmmse-16.2016.65 ID - Zhu2016/03 ER -