The Influence of Odevity of Carrier Ratio on Three-level Rectifier
- DOI
- 10.2991/icmmita-16.2016.14How to use a DOI?
- Keywords
- Three level rectifier; carrier ratio; transient current control; neutral point voltage; harmonic analysis.
- Abstract
Neutral point voltage balancing is an inherent problem of three-level rectifier. This paper first analyzed the cause to the neutral point voltage deviation of the DC-side three-level rectifier, and studied the charge and discharge transient processes of the two DC-side capacitors and the harmonic characteristics of the current of the AC-side rectifier respectively when the carrier ratio is an odd number or even number. It also verified its studies through simulation. The results showed that, when the carrier ratio is an even number, the neutral point voltage of the three-level rectifier is more easily to be balanced and will not cause bad influence on the harmonic characteristics of the AC-side rectifier.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Pengzhan Wang AU - Wei Luo AU - Shasha Yang AU - Tianzhi Cao AU - Huawei Li PY - 2017/01 DA - 2017/01 TI - The Influence of Odevity of Carrier Ratio on Three-level Rectifier BT - Proceedings of the 2016 4th International Conference on Machinery, Materials and Information Technology Applications PB - Atlantis Press SP - 68 EP - 73 SN - 2352-538X UR - https://doi.org/10.2991/icmmita-16.2016.14 DO - 10.2991/icmmita-16.2016.14 ID - Wang2017/01 ER -