A Water-cooled Radiator Driven by Memory Alloy
- DOI
- 10.2991/icmmita-15.2015.286How to use a DOI?
- Keywords
- Water-cooled electronic radiator; Ni-Ti memory alloy; Dual diameter pulley turbine; Cobweb model.
- Abstract
The traditional electronic equipment cooling system uses electric to drive water pump, it will consume energy. The motor operating power is constant, resulting in a waste of power. After cutting off the power supply, water pumps stop working so that the heat inside the appliance can’t be cleared. In this paper, use the recovery characteristics of shape memory alloy to create dual diameter pulley turbine, the two groups of alloy wires including heat coil and cold coil drive dual diameter pulley turbine rotating to form a pump system to replace the traditional water cooling system driven by an electric pump in order to save energy. Then the article analyses the system stability with Cobweb model. Realize the innovation of structure and principles. Enhance environmental protection of the water-cooled units.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Yang Liu PY - 2015/11 DA - 2015/11 TI - A Water-cooled Radiator Driven by Memory Alloy BT - Proceedings of the 2015 3rd International Conference on Machinery, Materials and Information Technology Applications PB - Atlantis Press SP - 1549 EP - 1552 SN - 2352-538X UR - https://doi.org/10.2991/icmmita-15.2015.286 DO - 10.2991/icmmita-15.2015.286 ID - Liu2015/11 ER -