Effects of blockage of the impeller channel on performances of non-overload centrifugal pump
- DOI
- 10.2991/icmemtc-16.2016.255How to use a DOI?
- Keywords
- Centrifugal pump; Blockage; Numerical research.
- Abstract
The shaft power curve of low specific-speed centrifugal pump is a steep rise with the increase of flow rate. The blockage of the impeller channel can reduce effectively the shaft power of low specific-speed centrifugal pump, and achieve pump's non-overload characteristics. In this paper, the flow channel of impeller was blocked three times, the characteristic curves of the four Plans were analyzed comparatively, the turbulent kinetic energy distribution of impeller channel was researched, and the change reasons of centrifugal pump's performance curves were further revealed. The results showed that blockage of the impeller channel can decrease shaft power, and to give reference for design of non-overload centrifugal pump.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Wanfang Zhao PY - 2016/04 DA - 2016/04 TI - Effects of blockage of the impeller channel on performances of non-overload centrifugal pump BT - Proceedings of the 2016 3rd International Conference on Materials Engineering, Manufacturing Technology and Control PB - Atlantis Press SP - 1303 EP - 1306 SN - 2352-5401 UR - https://doi.org/10.2991/icmemtc-16.2016.255 DO - 10.2991/icmemtc-16.2016.255 ID - Zhao2016/04 ER -