Power factor test for making and breaking experiment of mining low voltage electromagnetic starter
- DOI
- 10.2991/icmeit-17.2017.108How to use a DOI?
- Keywords
- Mining, starter, Making and breaking, Power factor, Phase angle difference.
- Abstract
Power factor is an important test condition for making and breaking capacities test of mining low voltage electromagnetic starter. Combing the reserves of coal resources with the development trend of coal industry, the structure, the application environment and the requirements of making and breaking capacities test for mining low voltage electromagnetic starter are introduced here. At the same time, we analyze the calculation method of power factor and the characteristics of direct reading method and phase angle difference method, design the making and breaking capacities test circuit used for mining low voltage electromagnetic starter, and verify the phase angle difference method used for testing power factor.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Shian Zhu PY - 2017/05 DA - 2017/05 TI - Power factor test for making and breaking experiment of mining low voltage electromagnetic starter BT - Proceedings of the 2nd International Conference on Mechatronics Engineering and Information Technology (ICMEIT 2017) PB - Atlantis Press SP - 591 EP - 595 SN - 2352-538X UR - https://doi.org/10.2991/icmeit-17.2017.108 DO - 10.2991/icmeit-17.2017.108 ID - Zhu2017/05 ER -