Experimental Investigation on Concealed Multi-ribbed Frame Thermal Insulation Wall under Eccentric Load
- DOI
- 10.2991/icmeim-17.2017.76How to use a DOI?
- Keywords
- Concealed Multi-ribbed Frame Thermal Insulation Wall, Eccentric load, Experimental Study, Cooperative Work, Failure Mode, Bearing Capability
- Abstract
Four models of Concealed multi-ribbed frame thermal insulation walls are manufactured at 1 /2 scale and then tested under eccentric load. The wall's failure processes is described. Cooperative working action, failure modes and bearing capability are analyzed to obtain the bearing capability calculation formula. Research indicates that the phenomenon of the wall's failure is coincide with reinforced concrete structures which under small and large eccentric load. The conclusion shows that the multi-ribbed frame and the blocks can work well together. The result of the calculation formula agrees conservatively with the test results. With high reliability, the formula may be used to calculate the bearing capability of this type of wall.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Ye-ke Luo PY - 2017/02 DA - 2017/02 TI - Experimental Investigation on Concealed Multi-ribbed Frame Thermal Insulation Wall under Eccentric Load BT - Proceedings of the 2017 International Conference on Manufacturing Engineering and Intelligent Materials (ICMEIM 2017) PB - Atlantis Press SP - 449 EP - 453 SN - 2352-5401 UR - https://doi.org/10.2991/icmeim-17.2017.76 DO - 10.2991/icmeim-17.2017.76 ID - Luo2017/02 ER -